FixVault

A/T Control Relay Check

  1. Remove the A/T control relay.
  2. Use jumper wires to connect the A/T control relay terminal 2 to the positive battery terminal and terminal 3 to the negative battery terminal.
  3. Check the continuity between terminal 1 and terminal 4 of the A/T control relay when the jumper wires are connected to and disconnected from the battery.
    Fig 1: Checking A/T Control Relay
    G02426139Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
    A/T CONTROL RELAY CONTINUITY

    JUMPER WIRE CONTINUITY BETWEEN TERMINALS NO. 1 AND NO. 4
    Connected Less than 2 ohm
    Disconnected Open circuit
  4. If there is any problem with the A/T control relay, replace it.