Transmission Fluid Temperature Sensor Check
- Remove the transmission fluid temperature sensor.
- Measure the resistance between terminals 1 and 2 of the transmission fluid temperature sensor connector.FLUID TEMPERATURE & RESISTANCE STANDARD VALUE CHART
TRANSMISSION FLUID TEMPERATURE RESISTANCE 0°C (32°F) 16.7 - 20.5 Ω 20°C (68°F) 7.3 - 8.9 Ω 40°C (104°F) 3.4 - 4.2 Ω 60°C (140°F) 1.9 - 2.2 Ω 80°C (176°F) 1.0 - 1.2 Ω 100°C (212°F) 0.57 - 0.69 Ω - If the transmission fluid temperature sensor resistance is outside the specified range and the "N" range indicator light is flashing, replace the transmission fluid temperature sensor.NOTE: The "N" range indicator light on the combination meter flashes when the temperature reaches approximately 125°C (257°F) or greater, and then stops flashing when the temperature drops below approximately 115°C (238°F).