FixVault

Actuator Test

ACTUATOR TEST

ITEM NO. CONTENTS OPERATION SPECIFICATIONS OPERATING DURATION DIAGNOSIS DETAILS
01 Bleeding Apply the current to the proportional valve according to the steering angel. 5 minutes Verify that no air comes out from the bleeder screw equipped in the ACD transfer.
03 Fluid capacity check Operate the proportional valve alternately in ON/OFF. 20 seconds Verify the fluid capacity in the reservoir tanks.
04 Electric pump operation Operate the electric pump for 5 seconds. Until end of operation Verify the operating condition of the electric pump with its operating sound.
05 ACD clutch operation check Operate the ACD, and supply the maximum hydraulic pressure to the multi-plate clutch. 1 minute With the wheels off the ground, verify the operation of the ACD clutch, judging from the rotational speed difference between front and rear wheels.
08 Control OFF De-energize the electric pump relay, and turn off the ACD control. - While driving the vehicle with the ACD in SNOW mode, compare the cornering performance with the control ON, then with the control OFF.