FixVault

Inspection (Disassembly And Assembly): Stator

  1. Check the continuity between coil leads.

    If there is no continuity, replace the stator.

    Fig 1: Checking Continuity Between Coil Leads
    G04296092Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  2. Check the continuity between coil and core.

    If there is no continuity, replace the stator.

    Fig 2: Checking Continuity Between Coil And Core
    G04296093Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.