FixVault

Electric Pump Relay Continuity Check

  1. Using a jumper wire, connect a battery (+) to terminal No.2 of the electric pump relay and battery (-) to terminal No.1.
  2. While intermittently disconnecting the jumper wire at the battery side, check for continuity between terminals No.3 and No.4 of the electric pump relay.
    TERMINAL REFERENCE

    JUMPER WIRE CONTINUITY BETWEEN TERMINAL NO.3 - NO.4
    Connected Less than 2 ohms
    Disconnected Open circuit
    Fig 1: Connecting Battery (+) To Terminal No.2 Of Electric Pump Relay And Battery (-) To Terminal No.1
    G04296678Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.