FixVault

Liftgate Lock Actuator Check

LIFTGATE LOCK ACTUATOR CHECK CHART

LEVER POSITION BATTERY CONNECTION LEVER OPERATION
At the "LOCK" position
  • Connect terminal No. 1 and the negative battery terminal.
  • Connect terminal No. 2 and the positive battery terminal.
The lever moves from the "LOCK" position to the "UNLOCK" position.
At the "UNLOCK" position
  • Connect terminal No. 2 and the negative battery terminal
  • Connect terminal No. 1 and the positive battery terminal.
The lever moves from the "UNLOCK" position to the "LOCK" position.
Fig 1: Checking Liftgate Lock Actuator
G04304132Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.