Battery Check: Notes
WARNING:
Battery posts, terminals and related accessories contain lead and lead compounds. WASH HANDS AFTER HANDLING. BATTERY VISUAL INSPECTION (1)
- Ensure that the battery electrolyte level A within the range B shown in the figure. Add if the level is lower than the specified range.
- Use a hydrometer and temperature gauge to check the specific gravity of the electrolyte.
Standard value: 1.220 - 1.290 [at 20°C (68°F)]
The specific gravity of electrolyte depends on its temperature. Use the formula below to determine the proper value.
Conversion on centigrade
D 20 =(t - 20) x 0.0007 + Dt
Conversion on Fahrenheit
D 20 =(t - 68) x 0.0007 + Dt
D20 : Specific gravity as if electrolyte temperature is 20°C (68°F)
Dt : Measured specific gravity
t : Measured temperature