FixVault

Liftgate Lock

TESTING LIFTGATE LOCK ACTUATOR

LEVER POSITION BATTERY CONNECTION LEVER OPERATION
At the "LOCK" position
  • Connect terminal No. 1 and the negative battery terminal.
  • Connect terminal No. 2 and the positive battery terminal.
The lever moves from the "LOCK" position to the "UNLOCK" position, and then returns to the "LOCK" position again.
At the "UNLOCK" position
  • Connect terminal No. 1 and the negative battery terminal.
  • Connect terminal No. 2 and the positive battery terminal.
The lever moves from the "UNLOCK" position to the "LOCK" position.
Fig 1: Identifying Liftgate Lock Actuator Connector Terminal
G04312758Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.