< Combination Meter >
COMBINATION METER SPECIFICATIONS
| ITEM | STANDARD VALUE | |
|---|---|---|
| Speedometer indication allowance range km/h (mph) | 16 (10) | 13.6 - 18.4 (8.5 - 11.5) |
| 40 (25) | 37.6 - 42.4 (23.5 - 26.5) | |
| 80 (50) | 77.6 - 82.4 (48.5 - 51.5) | |
| 120 (75) | 117.6 - 122.4 (73.5 - 76.5) | |
| 161 (100) | 158.5 - 165.0 (98.5 - 102.5) | |
| Tachometer indication allowance range r/min | 700 | +/- 100 |
| 3,000 | - 100 +225 | |
| 5,000 | - 125 +325 | |
| 6,000 | - 125 +375 | |
| Fuel level sensor resistance Q. | Float point "F" | 3 +/- 0.8 |
| Float point "E" | 110 +/- 2.5 | |
| Fuel level sensor float height mm (in) | A (Float point "F") | 24.1 +/- 2 (0.95 +/- 0.08) |
| B (Float point "E") | 151.6 +/- 2 (5.97 +/- 0.08) | |
| Engine coolant temperature gauge unit resistance Ω. | 70°C (150°F) | 104 + 13.5 |
| Combination meter internal resistance Ω, | Water temperature gauge to ground | 233 +/- 3 |
| Fuel gauge to ground | 181 +/-2 | |