Configuration Function
Use scan tool MB991958 to adjust the following functions. The programmed information is held even when the battery is disconnected.
SCAN TOOL OPERATION REFERENCE
| Adjustment item (scan tool display) | Adjustment item | Adjustment contents (scan tool display) | Adjusting contents |
|---|---|---|---|
| Alarm | With/without theft alarm function | Disable | Without function |
| Enable | With function (default) | ||
| Duration of prealarm | Adjustment of pre alarm continue time | 10 sec | 10 seconds (default) |
| 6 sec | 6 seconds | ||
| Panic alarm switch | With/without panic alarm function | Disable | Without function |
| Enable | With function (default) |