FixVault

Sensor - Input Speed: Installation

Fig 1: Identifying Output And Input Speed Sensors And Line Pressure Sensor
G04855997Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  1. Install the input speed sensor (3) into the transmission case.
  2. Install the bolt to hold the input speed sensor (3) into the transmission case. Tighten the bolt to 12 N.m (105 in. lbs.).
  3. Install the wiring connector onto the input speed sensor.
  4. Verify the transmission fluid level. Add fluid as necessary.
  5. Lower vehicle.