FixVault

Nominal Resistance Of The Fuel Level Sensor

WARNING: This page is about a different variant/trim than selected.
  1. Remove the fuel pump module (Refer to FUEL TANK ).
  2. When float of the fuel level sensor is in stopper positions F and E, ensure that resistance between the fuel level sensor terminal and ground terminal is within the standard value.

    Standard value: 

    FLOAT POSITION CHART

    Float position Gauge resistance value (ohms)
    Main Sub
    Stopper position "F" 6.5 ± 1.0 6.5 ± 1.0
    Stopper position "E" 41.9 ± 1.0 78.1 ± 1.0
  3. When the float is moved slowly between stopper positions "F" and "E", ensure that the resistance is smoothly changing.
    Fig 1: Checking Resistance Between Fuel Level Sensor Terminals
    G05396748Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.