FixVault

Rectifier Assembly <2.0L Engine>

Use the analog type tester to make sure the electrical continuity of each diode meets the table.

Unless the electrical continuity of each diode meets the table, replace the rectifier.

CONTINUITY CHART

(-) side (+) side Electrical continuity
E P1, P2, P3, P4, P5, P6 Yes
B No
P1, P2, P3, P4, P5, P6 E No
B Yes
Fig 1: Identifying Rectifier Assembly Terminals
G05393724Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.