Customization Function
Using the ETACS system of scan tool MB991958, the following functions can be programmed. The programmed information is held even when the battery is disconnected.
ITEM REFERENCE
| Adjustment item (scan tool MB991958 display) | Adjustment item | Adjusting contents (scan tool MB991958 display) | Adjusting contents |
|---|---|---|---|
| Door unlock mode | Adjustment of power door locks with selective unlocking | All doors unlock | Without function: The first operation of keyless entry system or unlock operation by KOS unlocks all doors. |
| Dr door unlock | With function: The first operation of keyless entry system or unlock operation by KOS unlocks the driver's door only, and the second unlock operation within 2 seconds after that unlocks all doors. (initial condition) | ||
| Auto door unlock | Adjustment of the auto door unlock function | Disabled | Without function (initial condition) |
| Always (P pos) | With function: Operates when the shift lever or the selector lever is moved to the P position. | ||
| P/W unlock (P) | With function: Operates when the shift lever or the selector lever is moved to the P position with the power window lock switch in the OFF position. | ||
| Always (Lock pos) | With function: Operates when the ignition switch is moved to the LOCK (OFF) position. | ||
| P/W unlock (Lock) | With function: Operates when the ignition switch is turned to the LOCK (OFF) position with the power window lock switch in the OFF position. |