FixVault

Inspection Instruments

For inspection, use the following instruments:

CAUTION: Never use a test light for checking ECU-related circuits or ECUs.
  1. Test light

    A test light consists of a 12V bulb and lead wires. It is used to check voltages or short circuits.

    Fig 1: Test Light
    G06698883Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  2. Self-powered test light

    A self-powered test light consists of a bulb, battery and lead wires connected in series. It is used to check continuity or grounding.

    Fig 2: Self-Powered Test Light
    G06698884Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
    CAUTION: Never use a jumper wire to connect a power supply directly to a load.
  3. Jumper wire

    A jumper wire is used to close an open circuit.

    Fig 3: Jumper Wire
    G06698885Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  4. Voltmeter

    A voltmeter is used to measure the circuit voltage. Normally, the positive (red lead) probe is applied to the point of voltage measurement and the negative (black lead) probe to the body ground. Use a digital voltmeter to check for voltage drop before or after a component.

    Fig 4: Checking Voltage Using Voltmeter
    G06698886Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  5. Ohmmeter

    An ohmmeter is used to check continuity or measure resistance of a switch or coil. If the measuring range has been changed, the zero point must be adjusted before measurement.

    Fig 5: Measuring Resistance Using Ohmmeter
    G06698887Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.