FixVault

Combination Meter

COMBINATION METER SPECIFICATION

ITEM STANDARD VALUE
Speedometer indication tolerance mph (km/h) <Except vehicles for CANADA> 10 (16) 8.5 - 11.5 (13.6 - 18.4)
25 (40) 23.5 - 25.5 (37.6 - 42.4)
50 (80) 48.5 - 51.5 (77.6 - 82.4)
75 (120) 73.5 - 76.5 (117.6 - 122.4)
100 (161) 98.5 - 102.5 (158.5 - 165.0)
Speedometer indication tolerance km/h (mph) <Vehicles for CANADA> 20 (12.4) 19 - 24 (11.8 - 14.9)
40 (24.8) 40 - 44 (24.8 - 27.3)
80 (49.7) 80 - 85 (49.7 - 52.8)
120 (74.6) 120.5 - 125.5 (74.9 - 78.0)
160 (99.4) 160.5 - 165.5 (99.7 - 102.8)
Tachometer indication tolerance r/min
The value in parentheses is a reference value.
600 500 - 700
(2, 000) (1, 900 - 2, 100)
3, 000 2, 850 - 3, 150
(4, 000) (3, 850 - 4, 150)
5, 000 4, 850 - 5, 150
6, 000 5, 850 - 6, 150
Fuel level sensor resistance Ω Fuel level sensor (main) Point "F" (highest) 6.5
Point "E" (lowest) 45.1
Fuel level sensor (sub) Point "F" (highest) 6.5 ± 1.0
Point "E" (lowest) 74.9 ± 1.0
Fuel level sensor float height mm (in) Fuel level sensor (main) A at point "F" 131.5 (5.1)
B at point "E" 34.5 (1.3)
Fuel level sensor (sub) A at point "F" 24.9 ± 3.0 (0.9 ± 0.1)
B at point "E" 172.7 ± 3.0 (6.7 ± 0.1)