Initialization Procedure

WARNING: This page is about a different car, the 2014 Mitsubishi Outlander. However, it is still accessible from the selected car via links, so may be relevant.

Required Special Tools: 

CAUTION: To prevent damage to the scan tool (M.U.T.-III), always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the scan tool (M.U.T.-III).
  1. After the ignition switch is in "LOCK" (OFF) position, connect scan tool (M.U.T.-III) to the data link connector.
  2. Turn the ignition switch to the "ON" position.
  3. Select "MFI" from System select Screen of the scan tool (M.U.T.-III).
  4. Select "Special Function" from MFI Screen.
  5. Select "Learned value reset" from Special Function Screen.
  6. Select "All learned value" from Learned value reset Screen.
  7. Initialize the learning value by pressing the "OK" button.
  8. After initializing the learning value, the learning value of MFI engine idling is necessary. (Refer to LEARNING PROCEDURE FOR IDLING IN MFI ENGINE  ).
    Fig 1: Identifying Data Link Connector And Special Tools
    G09663184Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.