Item Standard value Limit
Regulated voltage (Ambient temperature at voltage regulator) -20°C (-4°F) 14.2 - 15.4 -
20°C (68°F) 13.9 - 14.9 -
60°C (140°F) 13.4 - 14.6 -
80°C (176°F) 13.1 - 14.5 -
Generator output line voltage drop (at 30 A) V - Maximum 0.3
Output current - 70 % of normal output current
Field coil resistance Ω Approximately 2 - 5 -
Brush protrusion length mm (in) - Minimum 2 (0.08)