FixVault

Electronic Control Coupling Installation

WARNING: This page is about a different variant/trim than selected.
  1. Check that the length of the electronic control coupling stud bolt (A) is within the standard value range.

    Standard value: 21.6 - 24.4 mm (0.86 - 0.96 inch) 

  2. If it exceeds either of the limits, clean the threads for the electronic control coupling and replace the stud bolt.

    Tightening torque: 13 ± 2 N.m (115 ± 17 in-lb) 

    Fig 1: Identifying Electronic Control Coupling Stud Bolt Length
    G10223932Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.