FixVault

Service Specifications

WARNING: This page is about a different car, the 2018 Mitsubishi Outlander. However, it is still accessible from the selected car via links, so may be relevant.
Item Standard value Limit
Generator output line voltage drop (at 30 A) V - Maximum 0.3
Output current - 70 % of normal output current
Regulated voltage
(Ambient temperature at voltage regulator) <2.4L Engine>
-20°C (-4°F) 14.2 - 15.4 -
  20°C (68°F) 13.9 - 14.9 -
  60°C (140°F) 13.4 - 14.6 -
  80°C (176°F) 13.1 - 14.5 -
Regulated voltage
(Ambient temperature at voltage regulator) <3.0L Engine>
-20°C (-4°F) 14.0 - 15.1 -
  20°C (68°F) 13.7 - 14.6 -
  60°C (140°F) 13.2 - 14.3 -
  80°C (176°F) 12.9 - 14.1 -
Rotor resistance Ω 2.4L Engine 3 - 5 -
  3.0L Engine 2.1 - 2.4 -
Brush protrusion length mm (in) - Minimum 2 (0.1)