FixVault

Remote Controlled Mirror Switch Continuity Check

Switch position Tester connection Specified condition
Left side Up 1 - 6, 9 - 11 Continuity exists (2 ohms or less)
Down 1 - 11, 6 - 9
Right 1 - 6, 9 - 10
Left 1 - 10, 6 - 9
Right side Up 1 - 6, 3 - 9
Down 1 - 3, 6 - 9
Right 1 - 6, 2 - 9
Left 1 - 2, 6 - 9
Retract and extend 1 - 4
G06483733Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.