FixVault

Solenoid Valve Check

  1. While pressing A in the figure, turn B counterclockwise to unlock the CVT assembly connector, and disconnect the connector.
  2. Measure the resistance between the terminals of the applicable solenoid valves and ground.

    Standard value: 

    TERMINAL NUMBER APPLICABLE SOLENOID VALVE RESISTANCE VALUE Ω
    1 Line pressure solenoid valve
    • Approximately 5.3 Fluid temperature: 20°C (68°F)
    • Approximately 5.9 Fluid temperature: 50°C (122°F)
    • Approximately 6.5 Fluid temperature: 80°C (176°F)
    2 Primary pressure solenoid valve
    6 Low brake solenoid valve
    7 High clutch and reverse brake solenoid valve
    8 Lockup solenoid valve
    • Approximately 6.1 Fluid temperature: 20°C (68°F)
    • Approximately 6.8 Fluid temperature: 50°C (122°F)
    • Approximately 7.5 Fluid temperature: 80°C (176°F)
    CAUTION: Each solenoid valve cannot be removed or replaced as a single unit.
  3. When the resistance is outside the standard value, replace the valve body assembly (Refer to OIL PAN AND VALVE BODY ASSEMBLY  ).
G11278286Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.