FixVault

Inspection Procedure 1: Throttle Valve will not Fully Open or Close: Diagnosis

  1. STEP 1. Using scan tool MB991958, read the MFI system diagnostic trouble code (DTC). 
    CAUTION: To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.
    1. Connect scan tool MB991958 to the data link connector (Refer to , MFI Diagnosis - Diagnostic Function ) <2.0L ENGINE> or (Refer to , MFI Diagnosis - Diagnostic Function MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS ) <2.4L ENGINE>.
    2. Turn the ignition switch to the "ON" position.
    3. Set scan tool MB991958 to check for MFI system DTC (Refer to , MFI Diagnosis - Diagnostic Function MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS ) <2.0L ENGINE> or (Refer to , MFI Diagnosis - Diagnostic Function MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS ) <2.4L ENGINE>.

    Q: Is any DTC set? 

    YES:  Repair the MFI system (Refer to , MFI Diagnosis - DIAGNOSTIC TROUBLE CODE CHART ) <2.0L ENGINE> or (Refer to , MFI Diagnosis - DIAGNOSTIC TROUBLE CODE CHART ) <2.4L ENGINE>. Then go to Step  2.

    NO:  Go to Step  2.

  2. STEP 2. Check the symptom. 

    Q: Does the throttle valve fully open and close? 

    YES:  The procedure is complete.

    NO:  Return to Step  1.