FixVault

Check Initial Learning Quantity: Procedure

  1. Confirm that the power supply mode of the electric motor switch is OFF, and connect the scan tool (M.U.T.-III SE).
  2. Turn the power supply mode of the electric motor switch to ON (READY indicator: OFF).
  3. Confirm that the value of data list item No. 180: "Movement Range Learned Value" is within the standard value.

Standard value: 319 - 516