Individual Function Within The System

The electric shift sensor has eight non-contact sensors (Hall IC) built in. Each sensor switches ON/OFF according to the selector lever position.

SELECTOR LEVER POSITION JUDGMENT DESCRIPTION

Selector lever position Electric shift sensor
No. 1 No. 2 No. 3 No. 4 No. 5 No. 6 No. 7 No. 8
R ON ON OFF OFF OFF OFF OFF OFF
Nr ON ON ON ON ON OFF OFF OFF
H ON ON ON ON ON ON ON ON
Nd OFF OFF OFF ON ON ON ON ON
D/B OFF OFF OFF OFF OFF OFF ON ON