FixVault

Individual Function Within The System

The electric shift sensor has eight non-contact sensors (Hall IC) built in. Each sensor switches ON/OFF according to the selector lever position.

SELECTOR LEVER POSITION JUDGMENT

Selector lever position Electric shift sensor
No. 1  No. 2  No. 3  No. 4  No. 5  No. 6  No. 7  No. 8 
R ON ON OFF OFF OFF OFF OFF OFF
Nr ON ON ON ON ON OFF OFF OFF
H ON ON ON ON ON ON ON ON
Nd OFF OFF OFF ON ON ON ON ON