FixVault

Thermal Vacuum Valve

THERMAL VACUUM VALVE SPECIFICATIONS (1)

Application Open Below Open Between Closed Above
Sentra 60 (15) (2) 60 (15) & 122 (50) 122 (50)
Stanza, & 200SX 140 (60) N/A 140 (60)
(1) Specifications in °F (°C).
(2) Lower valve closed at this temperature.