Connect starter in series with a 12-volts battery, a voltmeter and a 1000-amp ammeter. Compare readings with appropriate STARTER NO LOAD SPECIFICATIONS table.

HITACHI STARTER NO LOAD SPECIFICATIONS

Application Max. Amps Min. RPM
Maxima
S114-461 100 3000
Pathfinder/Pickup
S114-516 90 2650
S114-605 60 7000
S114-607 100 7000
S114-606B 60 6000
S114-608D 60 6000
S114-453 100 3900
S114-454 100 3900
Pulsar NX
S114-475A 100 3900
S114-617A 60 7000
S114-520B 90 2950
Sentra
S114-475A 100 3900
S114-617A 60 7000
S114-520B 90 2950
240SX
S114-519A 100 2750
300ZX
S114-458 100 3900
MITSUBISHI STARTER NO LOAD SPECIFICATIONS

Application Max. Amps Min. RPM
Pathfinder/Pickup
M3T38482 60 6500
Pu7lsar NX
M1T70985 50-75 3000-4000
M1T72085 50-75 3000-4000
M2T53882 100 2900
M3T37782 60 6500
Sentra
M2T53882 100 2900
M3T37782 60 6500
M1T72085 50-75 3000-4000
Stanza
M2T53781 100 2750
240SX
M1T72781 50-75 3000-4000