FixVault

Idle Speed & Mixture

IDLE SPEED & CO LEVEL

Application Idle RPM CO Level
Pathfinder & Pickup
Automatic Transmission (1) 600-700 1.0-7.0%
Manual Transmission 750-850 1.0-7.0%
Pulsar NX SE
Automatic Transmission (1)(2) 650-750 Less than 5.0%
Manual Transmission (2) 750-850 Less than 5.0%
Pulsar NX XE
Automatic Transmission (1)(3) 625-725 3.0-10.0%
Manual Transmission (3) 675-775 3.0-10.0%
Sentra
Automatic Transmission (1) 575-675 3.0-10.0%
Manual Transmission 675-775 3.0-10.0%
Stanza
Automatic Transmission (1) 650-750 Less than 5.0%
Manual Transmission 700-800 Less than 5.0%
240SX
Automatic Transmission (4) 700-800 Less than 5.0%
Manual Transmission (5) 700-800 Less than 5.0%
(1) Automatic transmission in Drive.
(2) Adjust with AAC solenoid harness disconnected.
(3) Adjust with throttle sensor harness disconnected.
(4) Automatic transmission in Neutral.
(5) 650-750 RPM after engine code KA24-012039.
IDLE SWITCH SPEED

Application Engine RPM
Pathfinder & Pickup 1350-2150
Pulsar NX SE 800-1100
Pulsar NX XE & Sentra 1700-2000
Stanza N/A
240SX 850-1100