FixVault

Main Power Supply

Remove instrument cluster. Turn ignition on. Check voltage between ground and specified terminal of instrument cluster connector. See MAIN POWER SUPPLY TEST TERMINALS  table. See Figure-Figure . If battery voltage is not present, check for blown fuse, open fusible link, open in wiring harness, faulty ignition relay and/or faulty ignition switch.

MAIN POWER SUPPLY TEST TERMINALS

Application Terminal No.
Maxima 25
NX & Sentra
With Tachometer 12
Without Tachometer 17
Pathfinder & Pickup
With Voltmeter 2
Without Voltmeter 29
Stanza 25
240SX
With Analog Speedometer 24
With Electronic Speedometer 17
300ZX
With Options 29
Without Options 24