Starter - HITACHI: Overhaul: Commutator

Inspect commutator for roughness, grooves, burns, pitting and out-of-round. If necessary, sand lightly with 500-600 grit sandpaper. If mica insulator undercut is less than .008" (.20), undercut to .020-.031" (.50-.80 mm). Replace armature if commutator diameter is less than specified. See COMMUTATOR MINIMUM DIAMETER  table.

COMMUTATOR MINIMUM DIAMETER

Application In. (mm)
S114-630 1.54 (39)
S114-701B 1.26 (32)
S114-767 1.10 (28)
S114-769 1.10 (28)
Fig 1: Exploded View Of Starter S114-767/769 (Sentra)
G94E46171Courtesy of NISSAN MOTOR CO., U.S.A.
Fig 2: Exploded View Of Starter S114-701B (Sentra)
G92G00923Courtesy of NISSAN MOTOR CO., U.S.A.
Fig 3: Exploded View Of Starter S114-630 (Sentra)
G90C02750Courtesy of NISSAN MOTOR CO., U.S.A.