Door Switch Check
- Check Door Switch Input Signal
Using DVOM, measure voltage (backprobe) between ground and specified terminals at Smart Entrance Control Unit (SECU) harness connector. See DOOR SWITCH CIRCUIT TEST
table. If voltage is as specified, door switch is okay. If voltage is not as specified, go to next step.DOOR SWITCH CIRCUIT TEST
| Application (Terminal No.) |
Door Switch Condition |
Specification |
| Driver's Door (15) |
Open |
Zero Volts |
| " |
Closed |
Battery Voltage |
| All Doors (16) |
Open |
Zero Volts |
| " |
Closed |
Battery Voltage |
- Check Door Switch
Disconnect door switch in question. Using DVOM, check for continuity between specified door switch terminals. See DOOR SWITCH TEST
table. Replace door switch if continuity is not as specified. If continuity is as specified, check door switch ground circuit or door switch ground condition. Check for open or short in wiring harness between door switch and SECU. Repair as necessary.
DOOR SWITCH TEST
| Check Between Terminals No. |
Door Switch Condition |
Continuity |
| Driver's Door |
| 1 & 2 |
Open |
Yes |
| " |
Closed |
No |
| 3 & Ground |
Open |
Yes |
| " |
Closed |
No |
| Back Door |
| 1 & 2 |
Open |
Yes |
| " |
Closed |
No |
| Passenger Doors |
| 1 & Ground |
Open |
Yes |
| " |
Closed |
No |