Dynamic Damper
- Use a new damper band when reinstalling.
- Install dynamic damper from stationary-joint side while holding it securely:
- Length
- Unit: mm (in)
UNIT: MM (IN)Applied model QG18DE LH RH "A" 175-185 (6.89 - 7.28) 420-430 (16.54 - 16.93) "B" 70 (2.76) 64 (2.52) QR25DE "A" 173 - 179 (6.81 - 7.05) 200 - 206 (7.87 - 8.11) "B" 50 (1.97) 68 (2.68)