FixVault

With Consult-III

WARNING: This page is about a different car, the 2008 Nissan Quest. However, it is still accessible from the selected car via links, so may be relevant.
  1. Turn ignition switch ON.
  2. Turn ignition switch OFF and wait at least 10 seconds.
  3. Turn ignition switch ON and select "DATA MONITOR" mode with CONSULT-III.
  4. Make sure that the following conditions are met.

    COOLAN TEMP/S: 0 - 70°C (32 - 158°F) 

    INT/A TEMP SE: 0 - 30°C (32 - 86°F) 

  5. Select "EVAP SML LEAK P0442/P1442" of "EVAPORATIVE SYSTEM" in "DTC WORK SUPPORT" mode with CONSULT-III.

    Follow the instruction displayed.

    NOTE: If the engine speed cannot be maintained within the range displayed on the CONSULT-III screen, go to "BASIC INSPECTION ".
  6. Make sure that "OK" is displayed.

    If "NG" is displayed, refer to "DIAGNOSTIC PROCEDURE ".

    NOTE: Make sure that EVAP hoses are connected to EVAP canister purge volume control solenoid valve properly.