FixVault

Lock-Up Speed Specifications

LOCK-UP SPEED SPECIFICATIONS (2001 MODELS & 2002 QUEST) (1)

Application OD Switch MPH
Altima
Comfort Pattern
Lock-Up On In 4th ON 57-62
Lock-Up Off In 4th ON 47-52
Comfort Pattern
Lock-Up On In 3rd OFF 53-58
Lock-Up Off In 3rd OFF 52-57
Quest
Comfort Pattern
Lock-Up On In 4th ON 60-65
Lock-Up Off In 4th ON 48-53
Lock-Up On In 3rd OFF 53-58
Lock-Up Off In 3rd OFF 52-57
I30 & Maxima (2)
Comfort Pattern
Lock-Up On In 4th ON 31-36
(1) With 1/4 throttle opening.
(2) With 1/8 throttle opening.
LOCK-UP SPEED SPECIFICATIONS (2002 MODELS EXCEPT QUEST) (1)

Application Gearshift Lever Position MPH
Altima (2.5L)
Auto Power Or Comfort Pattern
Lock-Up On In 4th "D" 63-68
Lock-Up Off In 4th "D" 53-58
Auto Power Or Comfort Pattern
Lock-Up On In 3rd "3" 53-58
Lock-Up Off In 3rd "3" 52-57
Altima (3.5L)
Auto Power Or Comfort Pattern
Lock-Up On In 4th "D" 68-73
Lock-Up Off In 4th "D" 46-51
Auto Power Or Comfort Pattern
Lock-Up On In 3rd "3" 53-58
Lock-Up Off In 3rd "3" 52-57
I35 & Maxima
Auto Power Or Comfort Pattern
Lock-Up On In 4th "D" 62-66
Lock-Up Off In 4th "D" 39-43
Auto Power Or Comfort Pattern
Lock-Up On In 3rd "3" 53-58
Lock-Up Off In 3rd "3" 52-57
Sentra
Auto Power Or Comfort Pattern
Lock-Up On In 4th "D" 38-43
Lock-Up Off In 4th "D" 31-36
Auto Power Or Comfort Pattern
Lock-Up On In 3rd "3" 53-58
Lock-Up Off In 3rd "3" 52-57
(1) With 1/4 throttle opening.