FixVault

Operation Procedure

  1. Connect the CONSULT-II and CONVERTER to the data link connector and start the engine.
    CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.
  2. Touch "START (NISSAN BASED VHCL)" on the display screen.
  3. Touch "ABS".

    If "ABS" is not indicated, go to CONSULT-II DATA LINK CONNECTOR (DLC) CIRCUIT .

  4. Touch "ACTIVE TEST".
  5. The test item selection screen is displayed.
  6. Touch necessary test item.
    Fig 1: Identifying Scan Tool Display
    G00341458Courtesy of NISSAN MOTOR CO., U.S.A.
  7. With the "MAIN ITEM" display shown in reverse, touch "START".
  8. The Active Test screen will be displayed, so conduct the following test.