FixVault

1. Check EGR Volume Control Valve Power Supply Circuit

  1. Turn ignition switch OFF.
  2. Disconnect EGR volume control valve harness connector.
  3. Turn ignition switch ON.
    Fig 1: Disconnect EGR volume control valve harness connector
    G00877594Courtesy of NISSAN MOTOR CO., U.S.A.
  4. Check voltage between EGR volume control valve terminals 2, 5 and ground with CONSULT-II or tester.
    1. Voltage: Battery voltage 

OK or NG 

  1. OK: GO TO 3 .
  2. NG: GO TO 2.
Fig 2: Check voltage