FixVault

With CONSULT-II

  1. Start engine and warm it up to the normal operating temperature.
  2. Turn ignition switch OFF and wait at least 10 seconds.
  3. Start engine and keep the engine speed between 3,500 and 4,000 RPM for at least 1 minute under no load.
  4. Let engine idle for 1 minute.
  5. Select "HO2S2 (B1) P0139" or "HO2S2 (B2) P0159" of "HO2S2" in "DTC WORK SUPPORT" mode with CONSULT-II.
  6. Follow the instruction of CONSULT-II.
  7. Make sure that "OK" is displayed after touching "SELF-DIAG RESULTS".

    If NG is displayed, Refer to "DIAGNOSTIC PROCEDURE  ".

    If "CAN NOT BE DIAGNOSED" is displayed, perform the following.

  1. Turn ignition switch OFF and leave the vehicle in a cool place (soak the vehicle).
  2. Turn ignition switch ON and select "COOLAN TEMP/S" in "DATA MONITOR" mode with CONSULT-II.
  3. Start engine and warm it up while monitoring "COOLAN TEMP/S" indication on CONSULT-II.
  4. When "COOLAN TEMP/S" indication reaches to 70°C (158°F), go to step 3.
    Fig 1: Checking Voltage Between ECM Terminal 74 (HO2S2 Bank 1 Signal) Or 55 (HO2S2 Bank 2 Signal) And Engine Ground
    G00336443Courtesy of NISSAN MOTOR CO., U.S.A.