FixVault

With CONSULT-II: Notes

  1. Turn ignition switch ON and wait at least 1 second.
  2. Select "DATA MONITOR" mode with CONSULT-II.
  3. Start engine and let it idle for 1 second.
  4. Turn ignition switch OFF, wait at least 10 seconds, and then turn ON.
  5. Repeat steps 3 and 4 four times.
  6. If 1st trip DTC is detected, GO TO "DIAGNOSTIC PROCEDURE  " .
    Fig 1: Data Monitor Display
    G00780803Courtesy of NISSAN MOTOR CO., U.S.A.