Power Supply And Ground Circuit: Wiring Diagram

Fig 1: Wiring Diagram - EC-MAIN-01
G00775264Courtesy of NISSAN MOTOR CO., U.S.A.

Specification data are reference values and are measured between each terminal and ground.

CAUTION: Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Fig 2: Terminal Specifications
G00775265Courtesy of NISSAN MOTOR CO., U.S.A.
Fig 3: Wiring Diagram - EC-MAIN-02
G00775266Courtesy of NISSAN MOTOR CO., U.S.A.

Specification data are reference values and are measured between each terminal and ground.

CAUTION: Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Fig 4: Terminals Specification