Ambient Air Temperature Indication
With ignition switch ON position, trip computer displays ambient air temperature according to signal of ambient air temperature from unified meter and A/C amp. Unified meter and A/C amp. receives these signals from ambient air temperature sensor.
The ambient air temperature is displayed while the ignition switch is in the ON position.
Signal is supplied
- through ambient sensor terminal 1
- to unified meter and A/C amp. terminal 39
- through unified meter and A/C amp. terminal 10
- to triple meter terminal 5.
Indication range is between -30 and 55 °C (-22 and 131 °F). When ambient air temperature is less than -30 °C (-22 °F) or more than 55 °C (131 °F), display shows "-". When outside temperature is less than 3 °C (37 °F) continuously, display will "ICY" indicator illuminate as warning. In this case, the display will change to the ambient air temperature mode even though the display is showing a different mode. The "ICY" indicator will continue illuminate as long as the temperature remains below 4 °C (39 °F).