Diagnostic Procedure For Optical Sensor
SYMPTOM: Optical sensor circuit is open or shorted. Using the CONSULT-II, DTC B257F or B2580 is displayed. Without a CONSULT- II code 50 or 52 is indicated on front air control as a result of conducting self-diagnosis.
- CHECK VEHICLE EQUIPMENT
Is vehicle equipped with navi?
YES or NO
YES >> GO TO 2.
NO >> GO TO 4.
- CHECK CIRCUIT CONTINUITY BETWEEN OPTICAL SENSOR AND FRONT AIR CONTROL
- Turn ignition switch OFF.
- Disconnect front air control connector and optical sensor connector.
- Check continuity between optical sensor harness connector M402 terminal 1 and 2 and front air control harness connector M50 terminal 31 and 40.
1 - 31 : Continuity should exist .
2 - 40 : Continuity should exist .
- Check continuity between optical sensor harness connector M402 terminal 1 and 2 and ground.
1, 2 - Ground. : Continuity should not exist .
OK or NG
OK >> GO TO 3.
NG >> Repair harness or connector.
- CHECK CIRCUIT CONTINUITY BETWEEN OPTICAL SENSOR AND BCM
- Disconnect BCM connector.
- Check continuity between optical sensor harness connector (B) M402 terminal 3 and BCM harness connector (A) M18 terminal 18.
3 - 18 : Continuity should exist .
- Check continuity between optical sensor harness connector (A) M402 terminal 3 and ground.
3 - Ground : Continuity should not exist .
OK or NG
OK >> Replace optical sensor. Refer to "OPTICAL SENSOR ".
NG >> Repair harness or connector.
- CHECK CIRCUIT CONTINUITY BETWEEN OPTICAL SENSOR AND FRONT AIR CONTROL
- Turn ignition switch OFF.
- Disconnect front air control connector and optical sensor connector.
- Check continuity between optical sensor harness connector (B) M402 terminal 1 and 2 and front air control harness connector (A) M50 terminal 37 and 29.
1 - 37 : Continuity should exist .
2 - 29 : Continuity should exist .
- Check continuity between optical sensor harness connector M402 terminal 1 and 2 and ground.
1, 2 - Ground. : Continuity should not exist .
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
- CHECK CIRCUIT CONTINUITY BETWEEN OPTICAL SENSOR AND BCM
- Disconnect BCM connector.
- Check continuity between optical sensor harness connector (B) M402 terminal 3 and BCM harness connector (A) M18 terminal 18.
3 - 18 : Continuity should exist .
- Check continuity between optical sensor harness connector (A) M402 terminal 3 and ground.
3 - Ground : Continuity should not exist .
OK or NG
OK >> Replace optical sensor. Refer to "OPTICAL SENSOR ".
NG >> Repair harness or connector.