System Description: Notes
Power is supplied at all times
- to BCM terminal 7
- through 50A fusible link (letter F , located in the fuse and fusible link box).
- to key switch terminal 2
- through 10A fuse [No. 21, located in the fuse block (J/B)].
When key switch is ON (key is inserted in ignition key cylinder), power is supplied
- to BCM terminal 62
- through key switch terminal 1.
When the driver side door switch is ON (door is OPEN), ground is supplied
- to BCM terminal 14
- through driver side door switch terminal 1
- through driver side door switch case ground.
When the driver side door switch is ON (door is OPEN), ground is supplied (with navigation system)
- to combination meter terminal 7
- through driver side door switch terminal 1
- through driver side door switch case ground.
When the passenger side door switch is ON (door is OPEN), ground is supplied
- to BCM terminal 10
- through passenger side door switch terminal 1
- through passenger side door switch case ground.
When the passenger side door switch is ON (door is OPEN), ground is supplied (with navigation system)
- to BCM terminal 6
- through passenger side door switch terminal 1
- through passenger side door switch case ground.
When the door is locked and unlocked with power window main switch (door lock and unlock switch), ground is supplied
- to CPU of power window main switch
- through power window main switch (door lock and unlock switch) terminal 15
- through grounds M30 and M66.
Then power window main switch (door lock and unlock switch) operation signal is supplied
- to BCM terminal 74
- through power window main switch (door lock and unlock switch) terminal 12
When the door is locked and unlocked with power window sub-switch (door lock and unlock switch), ground is supplied
- to CPU of power window sub-switch
- through power window sub-switch (door lock and unlock switch) terminal 11
- through grounds M30 and M66.
Then power window sub-switch (door lock and unlock switch) operation signal is supplied
- to BCM terminal 74
- through power window sub-switch (door lock and unlock switch) terminal 16.
When the door is locked with door key cylinder switch, ground is supplied
- to power window main switch (door lock and unlock switch) terminal 6
- through door key cylinder switch terminal 1 and 5
- through grounds M30 and M66.
Then door key cylinder switch operation signal is supplied
- to BCM terminal 74
- through power window main switch (door lock and unlock switch) terminal 12.
When the door is unlocked with door key cylinder switch, ground is supplied
- to power window main switch (door lock and unlock switch) terminal 7
- through door key cylinder switch terminal 5 and 6
- through grounds M30 and M66.
Then door key cylinder switch operation signal is supplied
- to BCM terminal 74
- through power window main switch (door lock and unlock switch) terminal 12.
BCM is connected to power window main switch (door lock and unlock switch) and power window sub-switch (door lock and unlock switch) as serial link.