Inspection Procedure
WARNING: This page is about a different car, the 2003 Lexus LS 430. However, it is still accessible from the selected car via links, so may be relevant.
- Check MPX-B1, MPX-IG and D DOOR fuse.
CHECK:
Check continuity of MPX-B1, MPX-IG and D DOOR fuse.
OK:
Continuity
- NG : Replace faulty fuse.
- OK : Go to next step.
- Check voltage between terminals BDR, CPUB, SIG and GND of driver door ECU connector.
PREPARATION:
Turn the ignition switch ON.
CHECK:
Measure the voltage between terminals SIG and GND.
QK:
Voltage: 10 - 14 V
PREPARATION:
- Turn the ignition switch OFF.
- Disconnect the driver door ECU connector.
CHECK:
Measure the voltage between terminals BDR, CPUB and GND.
OK:
Voltage: 10 - 14 V
- OK : Proceed to next circuit inspection shown on problem symptoms table (See PROBLEM SYMPTOMS TABLE ).
- NG : Go to next step.
- Check wire harness and connector between ECU and body ground (See HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE
).
- NG : Repair or replace wire harness or connector.
- OK : Proceed to next circuit inspection shown on problem symptoms table (See PROBLEM SYMPTOMS TABLE ).