FixVault

With GST

  1. Lift up drive wheels.
  2. Start engine and warm it up to normal operating temperature.
  3. Turn ignition switch OFF and wait at least 5 seconds.
  4. Start engine and wait at least 70 seconds.
  5. Set voltmeter probes to ECM terminals 62 (EVAP control system pressure sensor signal) and ground.
  6. Check EVAP control system pressure sensor value at idle speed and note it.
  7. Establish and maintain the following conditions for at least 1 minute.
    Fig 1: Checking EVAP Control System
    G00869845Courtesy of NISSAN MOTOR CO., U.S.A.
    Fig 2: Condition Table
    G00869846Courtesy of NISSAN MOTOR CO., U.S.A.
  8. Verify that EVAP control system pressure sensor value stays 0.1V less than the value at idle speed (measured at step 6) for at least 1 second.
  9. If NG, go to Diagnostic Procedure .