FixVault

Throttle Position Sensor

With CONSULT-II 

  1. Start engine and warm it up to normal operating temperature.
  2. Stop engine (ignition switch OFF).
  3. Turn ignition switch ON.
  4. Select "DATA MONITOR" mode with CONSULT-II.
  5. Check voltage of "THRTL POS SEN" under the following conditions.

    Voltage measurement must be made with throttle position sensor installed in vehicle. 

Fig 1: Voltage Reference Chart
G00869394Courtesy of NISSAN MOTOR CO., U.S.A.
Fig 2: Displaying DATA MONITOR Mode
G00869395Courtesy of NISSAN MOTOR CO., U.S.A.

With GST 

  1. Start engine and warm it up to normal operating temperature.
  2. Stop engine (ignition switch OFF).
  3. Turn ignition switch ON.
  4. Check voltage between ECM terminal 23 (Throttle position sensor signal) and ground.

    Voltage measurement must be made with throttle position sensor installed in vehicle. 

Fig 3: Voltage Reference Chart
G00869396Courtesy of NISSAN MOTOR CO., U.S.A.