FixVault

DTC Confirmation Procedure

CAUTION: Be careful not to overheat engine.
NOTE: If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at least 5 seconds before conducting the next test.

With CONSULT-II 

  1. Turn ignition switch ON.
  2. Select "DATA MONITOR" mode with CONSULT-II.
  3. Check that "COOLAN TEMP/S" is above 10°C (50°F)

    If it is above 10°C (50°F), the test result will be OK. 

    If it is below 10°C (50°F), go to following step. 

  4. Start engine and run it for 65 minutes at idle speed.

    If "COOLAN TEMP/S" increases to more than 10°C (50°F) within 65 minutes, stop engine because the test result will be OK. 

  5. If 1st trip DTC is detected, go to Diagnostic Procedure .
Fig 1: Displaying DATA MONITOR Mode
G00869417Courtesy of NISSAN MOTOR CO., U.S.A.

With GST 

Follow the procedure "WITH CONSULT-II".