Diagnostic Procedure
- CHECK FUEL LEVEL SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect fuel level sensor unit harness connector.
- Turn ignition switch ON.
- Check voltage between fuel level sensor unit terminal 2 and ground with CONSULT-II or a tester.
- Voltage: Approximately 12V
OK or NG
- OK: GO TO 3.
- NG: GO TO 2.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors M91, B103
- Harness for open or short between combination meter and fuel level sensor unit
- Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK FUEL LEVEL SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Check harness continuity between fuel level sensor unit terminal 4 and body ground. Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to power.
OK or NG
- OK: GO TO 5.
- NG: GO TO 4.
- DETECT MALFUNCTIONING PART
Check harness for open or short between fuel level sensor unit and ground
- Repair open circuit or short to power in harness or connectors.
- CHECK FUEL LEVEL SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminal 46 and fuel level sensor unit terminal 2, ECM terminal 66 and ground. Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK: GO TO 7.
- NG: GO TO 6.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors M91, B103
- Harness connectors M81, F36
- Harness for open or short between ECM and ground
- Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK FUEL LEVEL SENSOR
Refer to FUEL WARNING SENSOR CHECK .
OK or NG
- OK: GO TO 8.
- NG: Replace fuel level sensor unit. See FUEL LEVEL SENSOR UNIT AND FUEL PUMP ASSEMBLY .
- CHECK INTERMITTENT INCIDENT
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .
- INSPECTION END.