FixVault

Procedure For Malfunction B And C

TESTING CONDITION: 

Before performing the following procedure, confirm that battery voltage is more than 11V at idle. 

With CONSULT-II 

  1. Start engine and warm it up to normal operating temperature.
  2. Turn ignition switch OFF and wait at least 5 seconds.
  3. Turn ignition switch ON again and select "DATA MONITOR" mode with CONSULT-II.
    Fig 1: Identifying Display
    G00870304Courtesy of NISSAN MOTOR CO., U.S.A.
  4. Start engine and run it for at least 1 minute at idle speed.
  5. If 1 ST trip DTC is detected, go to Diagnostic Procedure 

With GST 

Follow the procedure "With CONSULT-II".