Diagnostic Procedure
- With CONSULT-II: Malfunction code No. C1110
- Without CONSULT-II: Malfunction code No. 71
- INSPECTION START
ABS actuator and electric unit (control unit) power supply and ground circuit inspection.
- GO TO 2.
- CHECK CONNECTOR
- Disconnect ABS actuator and electric unit (control unit) connector E125.
Check terminals for deformation, disconnection, looseness or damage. Then reconnect connectors.
- Repeat self-diagnosis.
Does warning lamp activate again?
- YES: GO TO 3.
- NO: Inspection End.
- Disconnect ABS actuator and electric unit (control unit) connector E125.
- CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY CIRCUIT
Check voltage. Refer to "DIAGNOSTIC PROCEDURE ".
Does battery voltage exist when ignition switch is turned ON?
- YES: GO TO 4.
- NO: Repair.
- SELF-DIAGNOSIS RESULT CHECK
Check the self-diagnosis results.
- Malfunction code 71
- Diagnostic trouble code C1110
Are the above items indicated in self-diagnosis results?
- YES: Replace ABS actuator and electric unit (control unit). Refer to "REMOVAL AND INSTALLATION "
- NO: Inspect the system according to the indicated code No.